Low Cost for Permanent Installation
Low Cost, 2-Pin MIL Connector Accelerometers
-
Sensitivity: (±20%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 16 to 600000 cpm (0.27 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 2.8 oz (80 gm)
Model: 601A01
-
Sensitivity: (±20%) 500 mV/g (51.0 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 180000 cpm (0.5 to 3000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±10 g (±98 m/s²)
-
Weight: 1.8 oz (51 gm)
Model: 603C02
-
Sensitivity: (±20%) 500 mV/g (51 mV/(m/s²))
-
Frequency Range: (±3dB) 10 to 600000 cpm (0.17 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±10 g (±98 m/s²)
-
Weight: 2.8 oz (80 gm)
Model: 601A02
-
Sensitivity: (±20%) 50 mV/g (5.1 mV/(m/s²))
-
Frequency Range: (±3dB) 72 to 600000 cpm (1.2 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±100 g (±981 m/s²)
-
Weight: 1.8 oz (51 gm)
Model: 603C05
-
Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 480000 cpm (0.5 to 8000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 2.61 oz (74.0 gm)
-
Sensitivity: (±20%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 4.4 oz (124 gm)
Model: 602D01
Model: 606B01
-
Sensitivity: (±20%) 500 mV/g (51.0 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 180000 cpm (0.5 to 3000 Hz)
-
Measurement Range: ±10 g (±98 m/s²)
-
Electrical Connector: 2-Pin MIL-C-5015
Model: 602D02
-
Sensitivity: (±15%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 3.7 oz (105 gm)
Model: 607A01
-
Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 1.8 oz (51 gm)
Model: 603C01
-
Sensitivity: (±20%) 500 mV/g (51 mV/(m/s²))
-
Frequency Range: (±3dB) 10 to 600000 cpm (0.17 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±10 g (±98 m/s²)
-
Weight: 2.8 oz (80 gm)
Model: 601A92
-
Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 480000 cpm (0.5 to 8000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 2.61 oz (74.0 gm)
Model: 602D91
-
Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 1.95 oz (55 gm)
Model: 603C91
Low Cost Armored Cable
-
Sensitivity: (±20%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 16 to 600000 cpm (0.27 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 2.8 oz (80 gm)
Model: 603C91
Low Cost Integral Cable
-
Sensitivity: (±20%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 16 to 600000 cpm (0.27 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 2.8 oz (80 gm)
Model: 601A11
-
Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 480000 cpm (0.5 to 8000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 2.61 oz (74 gm)
Model: 602D61
-
Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 480000 cpm (0.5 to 8000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 2.61 oz (74.0 gm)
Model: 602D11
-
Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 1.8 oz (51 gm)
-
Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 1.8 oz (51 gm)
Model: 603C61
Model: 603C11
-
Sensitivity: (±20%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 4.4 oz (124 gm)
Model: 606B61
-
Sensitivity: (±20%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 4.4 oz (124 gm)
Model: 606B11
-
Sensitivity: (±15%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 1.1 oz (31 gm)
Model: 607A61
-
Sensitivity: (±15%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 1.1 oz (31 gm)
Model: 607A11
-
Sensitivity: (±15%) 100 mV/g (10.2 mV/(m/s²))
-
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
-
Sensing Element: Ceramic
-
Measurement Range: ±50 g (±490 m/s²)
-
Weight: 3.5 oz (99.3 gm)