High Sensitivity ICP® Accelerometers
-
Sensitivity: (±10%) 1000 mV/g (101.9 mV/(m/s²))
-
Measurement Range: ±5 g pk (±49 m/s² pk)
-
Broadband Resolution: 0.0001 g rms (0.001 m/s² rms)
-
Frequency Range: (±5%) 1 to 8000 Hz
-
Sensing Element: Ceramic
Model: 355B04
-
Sensitivity: (±5%) 1000 mV/g (102 mV/(m/s²))
-
Measurement Range: ±5 g pk (±49.1 m/s² pk)
-
Broadband Resolution: 0.00008 g rms (0.0008 m/s² rms)
-
Frequency Range: (±5%) 2 to 10000 Hz
-
Sensing Element: Ceramic
Model: 352B
Model: 393A03
-
Sensitivity: (±5%) 1000 mV/g (102 mV/(m/s²))
-
Broadband Resolution: 0.00001 g rms (0.0001 m/s² rms)
-
Measurement Range: ±5 g pk (±49 m/s² pk)
-
Frequency Range: (±5%) 0.5 to 2000 Hz
-
Electrical Connector: 2-Pin MIL-C-5015
-
Sensitivity: (±10%) 10000 mV/g (1019.4 mV/(m/s²))
-
Broadband Resolution: 0.000008 g rms (0.00008 m/s² rms)
-
Measurement Range: 0.5 g pk (4.9 m/s² pk)
-
Frequency Range: (±5%) 0.15 to 1000 Hz
-
Electrical Connector: 2-Pin MIL-C-5015
Model: 393B12
-
Sensitivity: (±10%) 1000 mV/g (102 mV/(m/s²))
-
Broadband Resolution: 0.000003 g rms (0.00003 m/s² rms)
-
Measurement Range: ±5 g pk (±49 m/s² pk)
-
Frequency Range: (±5%) 0.06 to 450 Hz
-
Electrical Connector: 10-32 Coaxial Jack
Model: 393B04
-
Sensitivity: (±10%) 10 V/g (1.02 V/(m/s²))
-
Broadband Resolution: 0.000004 g rms (0.00004 m/s² rms)
-
Measurement Range: 0.5 g pk (4.9 m/s² pk)
-
Frequency Range: (±5%) 0.7 to 450 Hz
-
Electrical Connector: 10-32 Coaxial Jack
Model: 393B05
-
Sensitivity: (±5%) 10.0 V/g (1.02 V/(m/s²))
-
Broadband Resolution: 0.000001 g rms (0.000009 m/s² rms)
-
Measurement Range: 0.5 g pk (4.9 m/s² pk)
-
Frequency Range: (±5%) 0.1 to 200 Hz
-
Electrical Connector: 2-Pin MIL-C-5015
Model: 393B31
-
Sensitivity: (±15%) 1000 mV/g (101.9 mV/(m/s²))
-
Broadband Resolution: 0.0001 g rms (0.001 m/s² rms)
-
Measurement Range: 2.5 g pk (24.5 m/s² pk)
-
Frequency Range: (±5%) 0.025 to 800 Hz (0.025 to 800 Hz)
-
Electrical Connector: 10-32 Coaxial Jack